25kWh 48V Battery

This guide covers 2 25kwh 48v battery actually in stock, priced from 14000 to 16500 SAR. A 25kWh pack delivers about 22.5kWh usable in lithium chemistry, and that is the figure that sets runtime. 48V is the practical standard for homes and farms: current is a quarter of a 12V system at the same power, so cable losses drop sharply. The bank must match a 48V inverter.

Products in stock

Available specifications and prices

Prices are in Saudi riyals as shown on the product pages, and specifications are taken from the product data itself.

ProductSpecificationsPrice (SAR)
بطارية ليثيوم 25 كيلو وات 500 أمبير 48 فولت LiFePO₄48V / 500Ah / 25kWh14000
بطارية ليثيوم فيليستي 25 كيلو واط 500 أمبير 48 فولت48V / 500Ah / 25kWh16500

Expected runtime

Formula: usable energy divided by load. Figures are estimates and drop 10-15% in high heat or at high discharge current.

LoadExpected runtime
0.5 kW45 h
1 kW22.5 h
2 kW11.3 h
3 kW7.5 h
5 kW4.5 h

Inverter compatibility

48V is the practical standard for homes and farms: current is a quarter of a 12V system at the same power, so cable losses drop sharply. The bank must match a 48V inverter.

Advantages

  • Up to 90% of nameplate capacity is usable
  • Several times the cycle life of lead acid
  • Lower weight and volume per kWh
  • Built-in BMS for protection and cell balancing

Points to consider

  • Higher upfront cost than lead acid
  • Requires an inverter with a lithium charge profile or correct manual settings
  • The BMS may derate charge current in extreme heat

Installation and usage considerations

Mount in shade with airflow around the enclosure, set charge and cut-off voltages to the manufacturer's figures, and never mix lithium packs of different ages or capacities on the same bus.

Use cable sized for the current with a short run between bank and inverter, plus a breaker or fuse on the positive terminal. Thin cable and long runs are the number-one cause of poor performance wrongly blamed on the battery.

How to pick the right option

Start from daily kWh and the hours you need, then divide by allowed depth of discharge (0.9 lithium, 0.5 gel) to get required nameplate capacity.

Fix the system voltage from your inverter, then compare options on price per usable kWh rather than price per unit.

Frequently asked questions

How long does a 25kWh battery run?

Usable energy is about 22.5kWh, roughly 23 hours at a 1kW load and about 11.3 hours at 2kW.

Will a 48V battery match my inverter?

48V is the practical standard for homes and farms: current is a quarter of a 12V system at the same power, so cable losses drop sharply. The bank must match a 48V inverter.

What is the current price range?

Options in this class start at 14000 SAR and reach 16500 SAR; the final price is shown on each product page.

Is technical advice available before buying?

Yes - send your load list and required hours over WhatsApp and we size the bank at no cost.