
5kWh 48V Battery
This guide covers 7 5kwh 48v battery actually in stock, priced from 2900 to 4900 SAR. A 5kWh pack delivers about 4.5kWh usable in lithium chemistry, and that is the figure that sets runtime. 48V is the practical standard for homes and farms: current is a quarter of a 12V system at the same power, so cable losses drop sharply. The bank must match a 48V inverter.
Products in stock
Available specifications and prices
Prices are in Saudi riyals as shown on the product pages, and specifications are taken from the product data itself.
| Product | Specifications | Price (SAR) |
|---|---|---|
| بطاريه 5 كيلو ليثيوم 48 فولت 100 أمبير ستار نوفا | 48V / 100Ah / 5kWh | 2900 |
| بطارية ليثيوم 100 أمبير 48 فولت بقدرة 5 كيلووات | 48V / 100Ah / 5kWh | 3300 |
| بطارية ليثيوم 6.0 كيلو وات (Go Green) بسعة 48 فولت | 48V / 6kWh | 3400 |
| بطارية ليثيوم 5.12 كيلو وات 100 أمبير 48 فولت LiFePO₄ | 48V / 100Ah / 5.12kWh | 3500 |
| بطارية ليثيوم بقدرة 5 كيلوواط 48 فولت Life PO4 | 48V / 5kWh | 3600 |
| بطارية ليثيوم طاقة شمسية متطورة 5.1 كيلوواط 100 أمبير ساعة | 48V / 100Ah / 5.1kWh | 3700 |
| بطارية ليثيوم (Go Green) بسعة 6.0 كيلو وات 48 فولت | 48V / 120Ah / 6kWh | 4900 |
Expected runtime
Formula: usable energy divided by load. Figures are estimates and drop 10-15% in high heat or at high discharge current.
| Load | Expected runtime |
|---|---|
| 0.5 kW | 9 h |
| 1 kW | 4.5 h |
| 2 kW | 2.3 h |
| 3 kW | 1.5 h |
| 5 kW | 0.9 h |
Inverter compatibility
48V is the practical standard for homes and farms: current is a quarter of a 12V system at the same power, so cable losses drop sharply. The bank must match a 48V inverter.
Advantages
- Up to 90% of nameplate capacity is usable
- Several times the cycle life of lead acid
- Lower weight and volume per kWh
- Built-in BMS for protection and cell balancing
Points to consider
- Higher upfront cost than lead acid
- Requires an inverter with a lithium charge profile or correct manual settings
- The BMS may derate charge current in extreme heat
Installation and usage considerations
Mount in shade with airflow around the enclosure, set charge and cut-off voltages to the manufacturer's figures, and never mix lithium packs of different ages or capacities on the same bus.
Use cable sized for the current with a short run between bank and inverter, plus a breaker or fuse on the positive terminal. Thin cable and long runs are the number-one cause of poor performance wrongly blamed on the battery.
How to pick the right option
Start from daily kWh and the hours you need, then divide by allowed depth of discharge (0.9 lithium, 0.5 gel) to get required nameplate capacity.
Fix the system voltage from your inverter, then compare options on price per usable kWh rather than price per unit.
Frequently asked questions
How long does a 5kWh battery run?
Usable energy is about 4.5kWh, roughly 5 hours at a 1kW load and about 2.3 hours at 2kW.
Will a 48V battery match my inverter?
48V is the practical standard for homes and farms: current is a quarter of a 12V system at the same power, so cable losses drop sharply. The bank must match a 48V inverter.
What is the current price range?
Options in this class start at 2900 SAR and reach 4900 SAR; the final price is shown on each product page.
Is technical advice available before buying?
Yes - send your load list and required hours over WhatsApp and we size the bank at no cost.
Related pages
Internal page ID: EN-BAT-000083









