QSSUN2kWh AGM Dry Batteries
This guide covers 10 2kwh agm dry batteries actually in stock, priced from 495 to 950 SAR. A 2kWh pack delivers about 1.8kWh usable in lithium chemistry, and that is the figure that sets runtime.
Products in stock
Available specifications and prices
Prices are in Saudi riyals as shown on the product pages, and specifications are taken from the product data itself.
| Product | Specifications | Price (SAR) |
|---|---|---|
| بطارية كيوصن جافة 100 امبير QSSUN DEEPCYCLE BATTERY 12V 100A | 12V / 100Ah / 1.2kWh | 495 |
| بطارية جل SCB طاقة جافة 100 امبير 12 فولت | 12V / 100Ah / 1.2kWh | 675 |
| بطارية كيوصن نحيفة 150 امبير - جافة FRONT TERMINAL BATTERY 12V 150A | 12V / 150Ah / 1.8kWh | 675 |
| بطارية كيوصن جافة 150 امبير QSSUN DEEPCYCLE BATTERY 12V 150A | 12V / 150Ah / 1.8kWh | 675 |
| بطارية جل SCB طاقة جافة 150 امبير 12 فولت | 12V / 150Ah / 1.8kWh | 750 |
| بطارية كيوصن جافة 200 امبير DEEPCYCLE BATTERY 12V 200A | 12V / 200Ah / 2.4kWh | 750 |
| بطارية ريتار طاقة جافة 200 امبير DEEPCYCLE RITAR BATTERY 12V 200A | 12V / 200Ah / 2.4kWh | 800 |
| بطارية جل نحيفة 12 فولت 150 أمبير NPP (فيتنام) | 12V / 150Ah / 1.8kWh | 900 |
| بطارية جل نحيفة 12 فولت 150 أمبير NPP (فيتنام) | 12V / 150Ah / 1.8kWh | 900 |
| بطارية NPP طاقة شمسية جل (12V 200Ah) أمبير فيتنام | 12V / 200Ah / 2.4kWh | 950 |
Expected runtime
Formula: usable energy divided by load. Figures are estimates and drop 10-15% in high heat or at high discharge current.
| Load | Expected runtime |
|---|---|
| 0.5 kW | 3.6 h |
| 1 kW | 1.8 h |
| 2 kW | 0.9 h |
| 3 kW | 0.6 h |
| 5 kW | 0.4 h |
Advantages
- High instantaneous discharge current for startup loads
- Sealed and safe for ventilated indoor installs
- Low price for intermittent backup duty
Points to consider
- Usable energy is roughly half of nameplate (50% DoD)
- Shorter cycle life that falls quickly with heat
- Heavier and bulkier per kWh
- Needs periodic full charging to avoid sulphation
Installation and usage considerations
Install in a ventilated spot out of direct sun, avoid discharging below 50%, and check each battery's voltage periodically - imbalance in a lead-acid bank destroys the whole bank.
Use cable sized for the current with a short run between bank and inverter, plus a breaker or fuse on the positive terminal. Thin cable and long runs are the number-one cause of poor performance wrongly blamed on the battery.
How to pick the right option
Start from daily kWh and the hours you need, then divide by allowed depth of discharge (0.9 lithium, 0.5 gel) to get required nameplate capacity.
Fix the system voltage from your inverter, then compare options on price per usable kWh rather than price per unit.
Frequently asked questions
How long does a 2kWh battery run?
Usable energy is about 1.8kWh, roughly 2 hours at a 1kW load and about 0.9 hours at 2kW.
What is the current price range?
Options in this class start at 495 SAR and reach 950 SAR; the final price is shown on each product page.
Is technical advice available before buying?
Yes - send your load list and required hours over WhatsApp and we size the bank at no cost.