How Long Does a 10kWh Battery Last?
Runtime = usable energy / load. A 10kWh lithium battery gives about 9kWh usable once depth of discharge and inverter losses are counted.
Products in stock
In depth
At a 1kW load (fridge, lights, TV, router) that is roughly 9 hours. At 2kW (add a split AC) about 4.5 hours. At 3kW about 3 hours.
High heat and high discharge current shave real runtime, so plan 10-15% below the theoretical figure.
If the 10kWh is gel nameplate, usable energy is around 5kWh - roughly half the runtime.
Related products with specs and prices
| Product | Specifications | Price (SAR) |
|---|---|---|
| بطاريه 10 كيلو ليثيوم 48 فولت 200 أمبير ستار نوفا | 48V / 200Ah / 10kWh | 4800 |
| بطارية ليثيوم (Go Green) 51.2 فولت 200 أمبير بقدرة 10 كيلووات | 51.2V / 200Ah / 10kWh | 5000 |
| بطارية NPP ليثيوم 200 أمبير – 48 فولت (10 كيلو واط) | 48V / 200Ah / 10kWh | 5400 |
| بطارية ليثيوم 10 كيلوواط 48 فولت 200 امبير LiFePO₄ | 48V / 200Ah / 10kWh | 5450 |
| بطارية EMPOWER ليثيوم 200 أمبير – 48 فولت (10.24 كيلوواط) | 48V / 200Ah / 10.24kWh | 5500 |
| (10 كيلو واط) بطارية ليثيوم 10KWH - 51.2V | 51.2V / 10kWh | 5550 |
| بطاريه Deye ليثيوم 10.2 كيلو 200 امبير 48 فولت | 48V / 200Ah / 9.6kWh | 6700 |
| بطاريه Deye ليثيوم 10.6 كيلو 200 امبير 48 فولت | 48V / 200Ah / 10.6kWh | 7200 |
Common mistakes to avoid
- Comparing amp-hours only and ignoring voltage, ending up with four times less energy than needed
- Discharging lead acid below 50%, which cuts life to less than half
- Picking a bank that does not match the inverter voltage, so charging fails or runs inefficiently
- Thin cable or a long run between bank and inverter, causing voltage drop and lost power
- Mixing new and old packs, or different capacities, on the same bus
Next step
Send your load list and required hours over WhatsApp, or use the on-site system calculator to size the battery bank and array.
Technical advice is free, and the recommendation is based on your real consumption, inverter voltage and installation location rather than on the largest battery in stock.
Frequently asked questions
How do I find my load in kW?
Add the nameplate power of everything running at once, or use the system calculator on this site.
Can I fully discharge it?
LiFePO4 can safely reach 90% thanks to the BMS, but repeated full discharge shortens life.