First requirement is voltage: a 48V inverter needs a 48V/51.2V bank and will not run on 24V or 12V.
Products in stock
In depth
Second is battery type in the inverter settings: it must support the lithium (or gel) charge profile, with charge and cut-off voltages set from the battery datasheet.
Third is current: the battery's maximum charge current must be at least what the inverter delivers, and its maximum discharge current must cover your peak load.
Fourth is communication: some hybrid inverters read battery state over CAN or RS485, which improves charge accuracy and prevents abrupt cut-offs.
Related products with specs and prices
| Product | Specifications | Price (SAR) |
|---|---|---|
| QSSUN AGM BATTERY 12V 7AH - UPS بطارية كيوصن 7 امبير | 12V | 45 |
| QSSUN AGM BATTERY 12V 9AH - UPS بطارية كيوصن 9 امبير | 12V | 58 |
| AGM BATTERY 12V 12AH - UPS بطارية كيوصن 12 امبير | 12V | 81 |
| QSSUN AGM BATTERY 12V 18AH - UPS بطارية كيوصن 18 امبير | 12V | 92 |
| QSSUN AGM BATTERY 12V 20AH - UPS بطارية كيوصن 20 امبير | 12V / 20Ah | 150 |
| بطاريه SCB جل 12 فولت 26 امبير فيتنامي | 12V / 26Ah | 183 |
| بطارية كيوصن للكراسي المتحركة 33 امبير AGM BATTERY 12V 33A | 12V / 33Ah | 191 |
| بطاريه NPP جل 12 فولت 26 امبير فيتنامي | 12V / 26Ah | 200 |
Common mistakes to avoid
- Comparing amp-hours only and ignoring voltage, ending up with four times less energy than needed
- Discharging lead acid below 50%, which cuts life to less than half
- Picking a bank that does not match the inverter voltage, so charging fails or runs inefficiently
- Thin cable or a long run between bank and inverter, causing voltage drop and lost power
- Mixing new and old packs, or different capacities, on the same bus
Next step
Send your load list and required hours over WhatsApp, or use the on-site system calculator to size the battery bank and array.
Technical advice is free, and the recommendation is based on your real consumption, inverter voltage and installation location rather than on the largest battery in stock.
Frequently asked questions
Can lithium run on an older inverter?
Only if charge voltages can be set manually to match the datasheet; otherwise the battery is at risk.
What if the inverter is stronger than the battery?
The BMS may cut out under high load; the battery's discharge rating must cover the inverter's output.
Related pages
- How Many Batteries Does a House Need?
- How Many Solar Panels to Charge a 10kWh Battery?
- How Long Does a 10kWh Battery Last?
- How Long Does a 15kWh Battery Last?
- Lithium Solar Batteries
- LiFePO4 Solar Batteries
- Gel Solar Batteries
- Solar Energy Storage Batteries
- 48V Solar Batteries
- How to Choose the Right Solar Battery
Internal page ID: EN-GUIDE-000016